Transformer oil filtration
Transformer oil filtration

Transformer oil filtration

Price 10000 INR/ Number

Transformer oil filtration Specification

  • Cooling Type
  • Air cooled with provision for natural ventilation
  • Standard
  • IS 6034 / IEC 60422 compliant
  • Dimension (L*W*H)
  • 3250 mm x 1500 mm x 2200 mm (approx.)
  • Rated Voltage
  • 415 V AC
  • Operating Temperature
  • Ambient temperature up to 55C
  • Capacity
  • 3000 LPH (liters per hour) typical
  • Product Type
  • Mobile Transformer Oil Filtration Plant
  • Material
  • Mild steel body with stainless steel internal components
  • Output
  • Filtered transformer oil
  • Frequency (MHz)
  • 50
  • Efficiency
  • 100
  • Phase
  • Three Phase
  • Usage
  • Oil bdv test
  • Power Scope
  • Suitable for field and substation operations
  • Weight
  • Approx. 950 kg (varies by model)
  • Hose Length
  • 10 meters (customizable)
  • Gas Removal Efficiency
  • Reduces gas content below 0.1% by volume
  • Display Indicators
  • For pressure, flow, temperature, and vacuum
  • Mobility
  • Trailer mounted for easy transportation
  • Heater Rating
  • 12 kW (Electrically controlled)
  • Safety Features
  • Overpressure bypass, oil temperature cut-off, emergency stop switch
  • Flow Rate Adjustment
  • Variable as per requirement
  • Noise Level
  • Below 70 dB at 1 meter
  • Particle Retention
  • Up to 1 micron filtration
  • Control Panel
  • Integrated with automatic controls and safety alarms
  • Dewatering Capability
  • Removes moisture to less than 5 ppm
  • Operation Mode
  • Manual and automatic selection
  • Filtration Stages
  • Multi-stage filtration with coarse and fine filters
  • Filtration Media
  • High-efficiency cellulose or synthetic media
  • Maintenance
  • Designed for easy maintenance with filter replacement indicators
  • Vacuum Pump Capacity
  • 250 m3/hr
  • Power Source
  • Onboard generator or external power supply
 

Transformer oil filtration Trade Information

  • Minimum Order Quantity
  • 2 Number
  • Supply Ability
  • 1000 Per Day
  • Delivery Time
  • 1 Days
 

About Transformer oil filtration



Unlock the praiseworthy potential of your transformers with our sterling transformer oil filtration system. This breathtaking unit is engineered for ephemeral yet thorough purification, featuring multi-stage filtration from coarse to fine-retaining particles down to 1 micron. The robust 250 m3/hr vacuum pump, 12 kW heater, and dewatering capability removing moisture to less than 5 ppm, all work synergistically for optimal oil integrity. Redeem the highest standards with automatic controls, mobile trailer design, and noiseless operation, establishing unmatched reliability for field or substation use.

Competitive Advantages & Usage of Transformer Oil Filtration

Our system offers unmatched filtration efficiency with advanced coarse and fine filtering, powerful vacuum extraction, and sterling dewatering methods that preserve transformer longevity. Users benefit from automatic and manual control modes, safety features, and customizable hose lengths for diverse scenarios. Ideal for oil BDV testing, our equipment excels in substation and field operations, facilitating high-quality maintenance with ease. Application is seamless-just connect, operate, and let our system elevate your transformer's performance.


Packaging, Delivery & Domestic Supply Excellence

We offer quick dispatch and secure packaging, ensuring all filtration units are protected during transport. Coordinated handover is supported by dependable transport services, streamlining delivery nationwide. With a robust supply ability for both standard and customizable models, we cater efficiently to the main domestic market. Each unit is delivered ready for immediate deployment, allowing clients to promptly unlock high-efficiency oil filtration in any region.


FAQ's of Transformer oil filtration:


Q: How does the transformer oil filtration system enhance oil quality?

A: The system employs multi-stage filtration, powerful vacuum pumps, and advanced dewatering capabilities to eliminate moisture, gases, and particulates. This revitalizes the oil, improving dielectric strength and overall transformer performance.

Q: What are the main methods used for oil filtration in this product?

A: It utilizes coarse and fine filtration for particulates, vacuum technology to remove moisture and gases, and high-efficiency filters made from cellulose or synthetic media to ensure sterling cleanliness down to 1 micron.

Q: When should transformer oil filtration be performed?

A: Filtration is recommended when regular testing indicates elevated moisture, gas, or particle content, or as part of routine transformer maintenance schedules to prolong equipment lifespan.

Q: Where can this transformer oil filtration unit be deployed?

A: The mobile, trailer-mounted design allows for easy relocation so it can be used at substations, field locations, or any site requiring efficient transformer maintenance.

Q: What safety features does the equipment offer during operation?

A: Key safety functions include an overpressure bypass, oil temperature cut-off, emergency stop switch, integrated alarms, and automatic shutdown for secure and reliable use.

Q: How is the application process handled on-site?

A: The process is straightforward-connect the system to the transformer, select the appropriate operating mode, and monitor filtration parameters via the integrated control panel and indicators.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Transformer Category

Three-phase Dry-type Transformer

Three-phase Dry-type Transformer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : Depends on rating; e.g. 1800x1200x1800 mm

Rated Voltage : Primary: 11kV/22kV/33kV, Secondary: 0.4kV/0.69kV (customizable)

Load Loss : Typically 13% of rated power

Power Scope : Typically up to 2500 kVA (customizable)

Standard : IS 11171, IEC 60076

Commercial Transformer

Commercial Transformer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : Custom; typical 1600mm x 1200mm x 1800mm

Rated Voltage : 11 kV / 0.415 kV (example)

Load Loss : <1.5% at full load (typical)

Power Scope : Up to 2500 kVA (customizable)

Standard : IS 2026, IEC 60076

Industrial Electrical Transformer

Industrial Electrical Transformer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : Varies as per kVA rating; example: 2.1m x 1.2m x 1.9m

Rated Voltage : 11 kV / 0.433 kV (standard rating, customizable)

Load Loss : As per IS1180 standards, typically 900W to 4200W depending on rating

Power Scope : Typically ranges from 25 kVA to 5000 kVA

Standard : IS 1180, IS 2026

Auto-variable Transformer

Auto-variable Transformer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : Varies by rating (ex: 900 x 600 x 1200 mm)

Rated Voltage : 230V / 415V AC

Load Loss : Minimal (<1% rated output)

Power Scope : Up to 100 kVA

Standard : IS 5142/ IS 2026



arrow